




Modbus RTU/TCP/ASCII Master and Slave ActiveX Control
Modbus RTU Master ActiveX Control
General specification for ActiveX Control
Support Windows 2000/Windows XP/Windows Vista which must have the VB6 runtime environment
Support most development environment which supports ActiveX or OLE design (Visual Basic/Visual C++/C#/VB.NET/VBA/C++ Builder/Delphi and so on)
Support to read and write Bit, Word, Long, Float, Double, Ascii char string, Wide char string.
Feature
»Able to connect up to 31 Modbus RTU Slaves via one com port
»Supported function code(Hex): 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x0F, 0x10
»Let user to config the address range about function code, read points, write points
»Support both Modbus address style and IEC61131 Syntax address style
»Support both Dec address style and Hex address style
»Runtime free
Modbus TCP Master ActiveX Control
General specification for ActiveX Control
Support Windows 2000/Windows XP/Windows Vista which must have the VB6 runtime environment
Support most development environment which supports ActiveX or OLE design (Visual Basic/Visual C++/C#/VB.NET/VBA/C++ Builder/Delphi and so on)
Support to read and write Bit, Word, Long, Float, Double, Ascii char string, Wide char string.
Feature
»Able to connect up to 31 Modbus TCP Slaves via tcp port
»Supported function code(Hex): 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x0F, 0x10
»Let user to config the address range about function code, read points, write points
»Support both Modbus address style and IEC61131 Syntax address style
»Support both Dec address style and Hex address style
»Runtime free
Modbus ASCII Master ActiveX Control
General specification for ActiveX Control
Support Windows 2000/Windows XP/Windows Vista which must have the VB6 runtime environment
Support most development environment which supports ActiveX or OLE design (Visual Basic/Visual C++/C#/VB.NET/VBA/C++ Builder/Delphi and so on)
Support to read and write Bit, Word, Long, Float, Double, Ascii char string, Wide char string.
Feature
»Able to connect up to 31 Modbus ASCII Slaves via one com port
»Supported function code(Hex): 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x0F, 0x10
»Let user to config the address range about function code, read points, write points
»Support both Modbus address style and IEC61131 Syntax address style
»Support both Dec address style and Hex address style
»Runtime free
Modbus RTU TCP ASCII Slave ActiveX Control
General specification for ActiveX Control
Support Windows 2000/Windows XP/Windows Vista which must have the VB6 runtime environment
Support most development environment which supports ActiveX or OLE design (Visual Basic/Visual C++/C#/VB.NET/VBA/C++ Builder/Delphi and so on)
Support to read and write Bit, Word, Long, Float, Double, Ascii char string, Wide char string.
Feature
»Support Modbus RTU/TCP/ASCII Slave which can communication with Modbus Master
»Able to create up to 16 Modbus RTU/ASCII Slaves via one com port
»Able to create up to 16 Modbus TCP Slaves via tcp port
»Supported function code(Hex): 0x01, 0x02, 0x03, 0x04, 0x05, 0x06, 0x08, 0x0F, 0x10
»Support both Modbus address style and IEC61131 Syntax address style
»Support both Dec address style and Hex address style
»Runtime free